Chapter 6 Parameter Descriptions 73
The complete CD signal is disabled in demo mode, general-purpose drive
operation mode and OD process.
2: Output signal 1 for complete OD
In OD process, when the drive receives OD location limiting signal or when
the pulse count number reaches the OD location limiting value, and at the
same time the drive torque reaches the setting of F023, the drive will output
signal 1 for complete OD.
The complete OD signal is disabled in demo mode, general-purpose drive
operation mode and CD process.
3: Output signal 1 for complete CD
In CD process, when the drive receives CD location limiting signal or when
the pulse count number reaches the CD location limiting value, and at the
same time the drive torque reaches the setting of F041, the drive will output
signal 1 for complete CD.
The complete CD signal is disabled in demo mode, general-purpose drive
operation mode and OD process.
4: Fault relay output 1
When the drive has fault, it will output fault relay output signal 1. But when
parameter setting error (E028) occurs, the drive only displays the alarm
information and will not output fault relay output signal 1.
5: Fault relay output 2
When the drive has fault or the drive's DC bus voltage is low (LED displays
"P.oFF"), it will output fault relay output signal 2. But when parameter setting
error (E028) occurs, the drive only displays the alarm information and will not
output fault relay output signal 2.
6: Output signal 2 for complete OD
In OD process, when the drive receives OD location limiting signal or when
the pulse count ed reaches the OD location limiting value, locking signal is
invalid and at the same time the drive torque reaches the setting of F023, the
drive will output signal 2 for complete OD.
The complete OD signal is disabled in demo mode, general-purpose drive
operation mode and CD process.
7: Output signal 2 for complete CD
TD3200 Variable Speed Drive for Elevator Door Control User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Network Power TD3200 Series and is the answer not in the manual?

Emerson Network Power TD3200 Series Specifications

General IconGeneral
BrandEmerson Network Power
ModelTD3200 Series
CategoryControl Unit
LanguageEnglish