86 Chapter 7 Application Guidance
Functions Name Setting Remark
F010 Start torque for OD 50.0%
F011 OD startup Acc time 1.0s
F012
Low speed in OD startup
process
10Hz
F013
Low-speed maintaining time
at OD startup
1.0s
F014
OD reference frequency
setting
35Hz
F015 OD Acc time 2.0s
F016
Initial time of S curve in OD
Acc process
20.0%
F017
Rising time of S curve in OD
Acc process
60.0%
F018 OD Dec time 2.0s
F019
Initial time of S curve in OD
Dec process
20.0%
F020
Dropping time of S curve in
OD Dec process
60.0%
F021
Low speed setting in OD
ending phase
3Hz
F022
Holding torque in complete
OD status
50.0%
F023
Threshold for torque
maintaining
50.0%
F024 Abnormal Dec time 0.5s
Parameters in the table are
factory settings, adjust the OD
parameters according to the
actual OD operating conditions.
TD3200 Variable Speed Drive for Elevator Door Control User Manual