G3 Series EtherCAT
TM
Technical Manual
13-131
TDG3ECM1-5EN 07/2020
Subject to change without notice
www.asco.com/g3
Connecting to a G3 Series EtherCAT
TM
Node (Windows 10)
This section will discuss how to connect a computer to a G3 Series EtherNet/IP
TM
node. There are multiple ways to
complete this task, so only two will be discussed. All computer commands are shown in Windows 10.
1. Connect a 24VDC power supply to the valve manifold. The connector pin-out can be found on the side of the
EtherNet/IP
TM
node or on page 4-20 of this document. (Note: 24VDC only needs to be applied to the
“+24VDC (NODE & INPUTS)” pin to power the node.)
2. Connect an Ethernet cable directly from the manifold to the computer -OR- Connect an Ethernet cable from
the manifold to a router, hub, or switch. Connect a second Ethernet cable from the computer to the router,
hub, or switch. (Network lights should appear on the router, hub, or switch if the correct cables are used).
3. Turn on the computer. Also, make sure the manifold and the router, hub, or switch has power.
4. To communicate with an EtherNet/IP
TM
manifold the IP address of your computer must be known. To start
this process, left click on the “Windows(Start) button.
5. Left click on Settings (gear icon), then on Network & Internet.

Table of Contents