G3 Series EtherCAT
TM
Technical Manual
5-40
TDG3ECM1-5EN 07/2020
Subject to change without notice
www.asco.com/g3
Advanced Settings - Diagnostic Word
This will allow the enabling / disabling of the Diagnostic Word Status bits. The Diagnostic word data includes power
status and sub-bus related status bits. Detailed information regarding these bits can be found on page 15-178. The
Diagnostic Word comes enabled from the factory.
Diag. Word Status Settings
1. Press the SET button to enter the ADVANCED SETTINGS menu.
2. Press the SET button to enter the ADVANCED MENU /SET STATUS.
3. Press the NEXT button to scroll to the SET STATUS / DIAG WORD
menu.
Press the SET button to enter the SET STATUS / DIAG WORD menu.
4. The current state of the parameter is shown.
5. Press the SET button to change this parameter
Use the NEXT button to scroll through the choices to enable/disable
the Diagnostic Word status for.
a. ENABLED (Factory Default)
b. DISABLED
c. RETURN (this will return you to the SET STATUS menu)
Press the SET button to confirm your choice.
6. Press NEXT to confirm the warning message.
7. Press the NEXT button to select Yes or No to accept the selection
a. Selecting No will bring you back to the main SET STATUS
menu.
b. Selecting Yes will take you to the following saved settings
menu.
Press the SET button to confirm your choice.
Save Settings Steps
8. Press the NEXT button to select either NOW or LATER.
a. Selecting NOW will cause the node to reset and apply the
new setting.
b. Selecting LATER will cause the new NODE DIAG selection
to be saved in memory, you must Accept the saved
changes before your next power cycle otherwise they will
be lost.
Press the SET button to confirm your choice.
ADVANCED
SETTINGS
ADVANCED MENU
SET STATUS
SET STATUS
IO STATUS
SET STATUS
DIAG WORD
DIAG WORD.
ENABLED
NODE DIAG.
DISABLED
NODE DIAG.
RETURN
INPUT MAPPING
WILL SHIFT!
ACCEPT
DISABLED Y N
SAVE SETTINGS
NOW LATER
DIAG WORD.
ENABLED

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Aventics G3 Series and is the answer not in the manual?

Emerson Aventics G3 Series Specifications

General IconGeneral
BrandEmerson
ModelAventics G3 Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals