198 Powerdrive F300 User Guide
Issue Number: 2
Parameter
Range(
Ú) Default(Ö)
Type
OL RFC-A RFC-S OL RFC-A RFC-S
05.001 Output Frequency
±VM_SPEED_
FREQ_REF Hz
±2000.0 Hz
RO Num ND NC PT FI
05.002 Output Voltage ±VM_AC_VOLTAGE V
RO Num ND NC PT FI
05.003 Output Power ±VM_POWER W
RO Num ND NC PT FI
05.004 Motor Rpm ±180000 rpm
RO Num ND NC PT FI
05.005 D.C. Bus Voltage ±VM_DC_VOLTAGE V
RO Num ND NC PT FI
05.006 Rated Frequency 0.0 to 550.0 Hz
50Hz: 50.0
60Hz: 60.0
RW Num US
05.007 Rated Current ±VM_RATED_CURRENT Maximum Rated Current 11.060 RW Num RA US
05.008 Rated Speed 0 to 33000 rpm 0.00 to 33000.00 rpm
Eur - 1500
rpm
USA -
1800 rpm
Eur -
1450.00
rpm
USA -
1750.00
rpm
3000.00
rpm
RW Num US
05.009 Rated Voltage ±VM_AC_VOLTAGE_SET V
200 V drive: 230 V
Eur - 400 V drive: 400 V
USA - 400 V drive: 460 V
575 V drive: 575 V
690 V drive: 690 V
RW Num RA US
05.010 Rated Power Factor 0.000 to 1.000
0.850 RW Num RA US
05.011 Number Of Motor Poles Automatic (0) to 480 Poles (240) Automatic (0) 6 Poles (3) RW Txt US
05.012 Autotune 0 to 2 0 to 3 0 to 4 0 RW Num NC
05.013
Dynamic V To F Select /
Flux Optimization Select
Off (0) or On (1)
Off (0) RW Bit US
05.014
Open-loop Control Mode /
Action On Enable
Ur S (0), Ur (1),
Fixed (2), Ur Auto
(3), Ur I (4),
Square (5),
Current 1P (6)
Disabled (0),
Short (1),
Short Once (2),
Long (3),
Long Once (4)
Ur I (4)
Disabled (0) RW Txt US
05.015
Low Frequency Voltage
Boost
0.0 to 25.0 %
3.0 % RW Num US
05.017 Stator Resistance 0.000000 to 1000.000000 Ω 0.000000 Ω RW RA US
05.018
Maximum Switching
Frequency
2 kHz (0), 3 kHz (1), 4 kHz (2), 6 kHz (3),
8 kHz (4), 12 kHz (5), 16 kHz (6)
3 kHz (1) RW Txt RA US
05.019
High Stability Space Vector
Modulation
Off (0) or On (1)
Off (0)
RW Bit US
05.020 Quasi-square Enable
RW Bit US
05.022 Enable High Speed Mode
Limit (-1),
Disable (0),
Enable (1)
Limit (-1) RW Bit US
05.024 Transient Inductance / Ld 0.000 to 500.000 mH 0.000 mH RW Num RA US
05.025 Stator Inductance 0.00 to 5000.00 mH
0.00 mH RW Num RA US
05.027 Enable Slip Compensation Off (0) or On (1) On (1) RW Bit RA US
05.031 Voltage Controller Gain 1 to 30 1 RW Num US
05.033 Volts per 1000 rpm
0 to 10000 V 98 V RW Num US
05.034 Percentage Flux
0.0 to 150.0 % RO Num ND NC PT
05.035
Auto-switching Frequency
Change Disable
Enabled (0), Disabled (1), No Ripple Detect (2) Enabled (0) RW Txt US
05.036
Auto-switching Frequency
Step Size
1 to 2 2 RW Num US
05.037 Switching Frequency
2 kHz (0), 3 kHz (1), 4 kHz (2), 6 kHz (3),
8 kHz (4), 12 kHz (5), 16 kHz (6)
RO Txt ND NC PT
05.038
Minimum Switching
Frequency
0 to VM_MIN_SWITCHING_FREQUENCY kHz 2 kHz (0) RW Txt US
05.039
Maximum Inverter
Temperature Ripple
20 to 60 °C 60 °C
05.040 Spin Start Boost 0.0 to 10.0 1.0 RW Num US
05.041 Voltage Headroom
0 to 20 % 0 % 10 % RW Num US
05.042
Reverse Output Phase
Sequence
Off (0) or On (1) Off (0) RW Bit US
05.064 RFC Low Speed Mode
Injection (0),
Non-salient (1)
Non-
salient (1)
RW Txt US
05.065 Saliency Torque Control
Disabled (0),
low (1),
high (2)
Off (0) RW Bit US