Powerdrive F300 User Guide 199
Issue Number: 2
05.067
Percentage Over-current Trip
Level
10 (0), 20 (1),
30 (2), 40 (3),
50 (4), 60 (5),
70 (6), 80 (7),
90 (8),
100 (9) %
100 (9) % RW Txt US
05.070
Inverted Saturation
Characteristic
Off (0) or On
(1)
Off (0) RW Bit US
05.071
Low Speed Sensorless Mode
Current Limit
0.0 to 1000.0
%
20.0 % RW Num RA US
05.072 No-load Lq
0.000 to
500.000 mH
0.000 mH RW Num RA US
05.075
Iq Test Current For
Inductance Measurement
0 to 200 % 100 % RW Num US
05.077
Phase Offset At Iq Test
Current
±90.0 ° 0.0 ° RW Num RA US
05.078
Lq At The Defined Iq Test
Current
0.000 to
500.000 mH
0.000 mH RW Num RA US
05.082
Id Test Current for Inductance
Measurement
-100 to 0 % -50 % RW Num US
05.084
Lq At The Defined Id Test
Current
0.000 to
500.000 mH
0.000 mH RW Num RA US
05.088 Estimated Lq
0.000 to
500.000 mH
RO Num ND NC PT FI
05.089 Rated Torque Angle
0 to 90 ° RO Num ND NC PT
Parameter
Range(
Ú)Default(Ö)
Type
OL RFC-A RFC-S OL RFC-A RFC-S
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination