CG Drives & Automation 01-7492-01r1 Functional description 109
Crane [257]
Crane deviation [2571]
Deviation delay time, starts counting when the fault is gone.
When the time delay has elapsed, the alarm will be reset if
the function is active.
Crane Communication [2572]
Crane Communication delay time, starts counting when the
fault is gone. When the time delay has elapsed, the alarm
will be reset if the function is active.
External Trips [258]
External Trip 1 [2581]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
External Trip 1 Type [2582]
Select the preferred way to react to an alarm trip.
External Trip 2 [2583]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
External Trip Type 2 [2584]
Select the preferred way to react to an alarm trip.
External Trip 3 [2585]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
External Trip 3 Type [2586]
Select the preferred way to react to an alarm trip.
External Trip 4 [2587]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
External Trip Type 4 [2588]
Select the preferred way to react to an alarm trip.
2571 CraneDeviat
Default: Off
Range: Off, 1–3600 s (Off=0)
2572 Crane Comm
Default: Off
Range: Off, 1–3600 s (Off=0)
2581 Ext Trip 1
Default: Off
Range: Off, 1–3600 s (Off=0)
2582 ExtTrip1 TT
Default: Trip
Trip 0 The motor will coast
Decele-
ration
1 The motor will decelerate
2583 Ext Trip 2
Default: Off
Range: Off, 1–3600 s (Off=0)
2584 ExtTrip2 TT
Default: Trip
Trip 0 The motor will coast
Decele-
ration
1 The motor will decelerate
2585 Ext Trip 3
Default: Off
Range: Off, 1–3600 s (Off=0)
2586 ExtTrip3 TT
Default: Trip
Trip 0 The motor will coast
Decele-
ration
1 The motor will decelerate
2587 Ext Trip 4
Default: Off
Range: Off, 1–3600 s (Off=0)
2588 ExtTrip4 TT
Default: Trip
Trip 0 The motor will coast
Decele-
ration
1 The motor will decelerate