EasyManua.ls Logo

Endress+Hauser Proline Promag 55 - Page 19

Endress+Hauser Proline Promag 55
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promag 55 PROFIBUS DP/PA Installation
Endress+Hauser 19
Flow rate characteristic values - Promag S (US units)
Nominal
diameter
Recommended flow rate Factory settings
[inch]
min./max. full scale value
(v 1.0 or 33 ft/s)
Low flow cut off
(v 0.1 ft/s)
½" 1.0…27 gal/min 0.10 gal/min
1" 2.5…80 gal/min 0.25 gal/min
1 ¼" 4…130 gal/min 0.50 gal/min
1 ½" 7…190 gal/min 0.75 gal/min
2" 10…300 gal/min 1.25 gal/min
2 ½" 16…500 gal/min 2.0 gal/min
3" 24…800 gal/min 2.5 gal/min
4" 40…1250 gal/min 4.0 gal/min
5" 60…1950 gal/min 7.0 gal/min
6" 90…2650 gal/min 12 gal/min
8" 155…4850 gal/min 15 gal/min
10" 250…7500 gal/min 30 gal/min
12" 350…10600 gal/min 45 gal/min
14" 500…15000 gal/min 60 gal/min
16" 600…19000 gal/min 60 gal/min
18" 800…24000 gal/min 90 gal/min
20" 1000…30000 gal/min 120 gal/min
24" 1400…44000 gal/min 180 gal/min

Table of Contents