Proline Promass F 300 EtherNet/IP Commissioning
157
Parameter Prerequisite Description Selection / User
entry
Factory setting
Oscillation
amplitude 1
Frequency
fluctuation 0
Frequency
fluctuation 1
Oscillation
damping 0
Oscillation
damping 1
Oscillation
damping
fluctuation 0
Oscillation
damping
fluctuation 1
Signal asymmetry
Exciter current 0
Exciter current 1
HBSI
Totalizer 1
Totalizer 2
Totalizer 3
Current output 1
Current output 2
*
Current output 3
*
Current output 4
*
Pressure
Decimal places 4 A measured value is specified
in the Value 4 display
parameter.
Select the number of decimal
places for the display value.
x
x.x
x.xx
x.xxx
x.xxxx
x.xx
Display language A local display is provided. Set display language. English
Deutsch
*
Français
*
Español
*
Italiano
*
Nederlands
*
Portuguesa
*
Polski
*
русский язык
(Russian)
*
Svenska
*
Türkçe
*
中文 (Chinese)
*
日本語
(Japanese)
*
한국어 (Korean)
*
Bahasa Indonesia
*
tiếng Việt
(Vietnamese)
*
čeština (Czech)
*
English
(alternatively, the
ordered language is
preset in the device)
Display interval A local display is provided. Set time measured values are
shown on display if display
alternates between values.
1 to 10 s 5 s
Display damping A local display is provided. Set display reaction time to
fluctuations in the measured
value.
0.0 to 999.9 s 0.0 s