Epson Artisan 700/Epson Stylus Photo PX700W/TX700W Revision C
DISASSEMBLY/ASSEMBLY Disassembly Procedures 106
Confidential
4.2.2.4 Upper Left Housing / Panel Lock Button
Parts/Components need to be removed in advance:
None
Removal procedure
1. Remove the screw (x1) that secures the Upper Left Housing.
2. Release the hooks (x2) and rib
s (x2) of the Upper Left Housing and remove
the Upper Left Housing.
Figure 4-13. Removing the Upper Left Housing
3. Rem
ove the Panel Lock Button.
Figure 4-14. Removing the Panel Lock B
utton
C H E C K
P O I N T
The disassembly/reassembly procedures of Artisan 700/PX700W/
TX700W differ from those of Artisan 800/PX800FW/TX800FW.
See 4.3.1.2 "Upper Left Housing (Artisan 700/PX700W/TX700W)"
(p187) for the procedures.
C.B.P. 3x10 (black) (6±1Kgfcm)
Upper Left Housing
Hook
Rib
Panel Lock Button