4-34
EMP-TW1000
SEIKO EPSON Revision:A
4.2.13 Removing the Motor CF Assy., CF SW Assy., Micro SW Assy., Top
ML Fasten Spring, Frame CF Assy., and Auto Iris Assy.
1. Remove the two screws (C.B.P-TITE SCREW, 3x10, F/ZB-3C) that secure the Motor CF
Assy., and remove the Motor CF Assy. from the Optical Engine.
2. Remove the two screws (C.B.P-TITE SCREW, 3x10, F/ZB-3C) that secure the CF SW
Assy, and remove the CF SW Assy.
3. Remove the Top ML Fasten Spring from the CF SW Assy.
4. Remove the two screws (C.P. SCREW, 1.6x6, F/ZN-3C) that secure the Micro SW Assy.,
and remove the Micro SW Assy. form the CF SW Assy.
5. Remove the Frame CF Assy.
6. Remove the three screws (SCREW,AI FASTEN) that secure the Auto Iris Assy., and
remove the Auto Iris Assy.
Figure 4-33.
SW CF Assy.
Frame CF Assy.
Motor CF Assy.
C.P. SCREW, 1.6x6, F/ZN-3C
Auto Iris Assy.
Spring, ML Fasten, Top
SCREW,AI FASTEN
Micro SW Assy.