EPSON Stylus Scan 2000
Revision A
Disassembly & Assembly
Disassembly Procedures
102
4.2.4.4 Removing the scanner motor
1. Remove the scanner as described in “Removing the Scanner Mechanism” on page99.
2. Cut the plastic clip securingthe cables.
3. Remove two screws (CBP 3x6 with plain washer).
4.2.4.5 Removing the upper frame
Removing the upper frame can make some procedures such as removing the printhead
easier, but is not required.
1. Remove the upper cover as described in Section 4.2.1.4.
2. Remove the scanner as described in “Removing the Scanner Mechanism” on page99.
3. If you have not already removed it, remove one screw (CBP 3x6) securing the carriage
guard and then remove the guard. Also remove two screws (CBP 3x6) securing the
upper frame on the left side.
n Make sure the motor cable wraps around the back of the motor,
as shown in step 2.
n Replace the cables with a new plastic clip when reinstalling the
scanner motor as shown in steps 2 and 3.
Cut this
clip.
Motor
cable
Remove two screws.
First remove this
screw and the
carriage guard.
Then remove
these screws.
When re-
installing the
carriage
guard, insert
this knob into
the upper
hole.
Carriage
guide

Table of Contents

Other manuals for Epson Stylus Scan 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson Stylus Scan 2000 and is the answer not in the manual?

Epson Stylus Scan 2000 Specifications

General IconGeneral
BrandEpson
ModelStylus Scan 2000
CategoryAll in One Printer
LanguageEnglish

Related product manuals