EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Removing the Circuit Boards 107
Confidential
4.4.3.3 Button/ Power Lens/ Mall Panel
1. Remove the Panel Board and Panel Board B.
(Refer to "4.4.3.1 Panel Board/ Panel Board B (p105)")
2. Remove the Buttons (x30) shown below from the Panel Cover by releasing
the hooks.
3. Remove the screw and remove the Power Lens.
4. Remove the Mall Panel from the Panel Cover.
Figure 4-36. Removing the Button/ Power Lens/ Mall Panel
4.4.3.4 Panel Shaft
1. Remove the Panel Lower Housing.
(Refer to "4.4.3.1 Panel Board/ Panel Board B (p105)")
2. Release the ribs (x2) of the Panel Shafts (x2) from the grooves (x2) of the
Panel Lower Housing and remove the Panel Shafts (x2) and Panel Shaft
Springs (x2) from the Panel Lower Housing.
Figure 4-37. Removing the Panel Shaft
No.
Button
No.
Button
1 Power button 8 Start button
2 Display/Crop button 9 Redial/Pause button
3 Minus Button, Plus Button 10 Back button
4 Ten keys 11 Cross Key and OK button
5 Auto Answer/Space button 12 Menu button
6 Speed Dial/Group Dial/Back Space button 13 Auto Correct button
7 Stop/Clear Settings button 14 Top menu button
21 3 4 5 6
7
89
11 10121314
Mall Panel Power Lens
C.B.P. 2x6, F/Zn-3C (6±1kgfcm)
Back side
When installing the Buttons, engage the hook of each Button
securely to the Panel Cover. After assembling the Panel Unit, press
all the Buttons and confirm they click.
Panel Lower Housing
Panel Shaft, Panel Shaft Spring
Panel Shaft Spring
Rib
Panel Shaft

Table of Contents