-- 4 9 --cdte1de1
Terminal XT11 is mounted on the side of the ferrite core of the main
transformer TM01.
2. Connect an oscilloscope or a multimeter across capacitor C09.
3. Disconnect wire 110 from the discharge resistor R03.
4. Load the machine with a resistive load and start it in AC mode. Set the
current to 50A. Slowly increase the current until the voltage is 570 -- 580V.
The machine should then stop and the yellow Error LED on the front panel
should light. If the machine does not stop, adjust with R301 until it does.
5. Switch off the machine, connect wire 110 to R03.
6. Load the machine with a resistive load and start it in AC mode. Set the
current to 50A. Slowly increase the current until the voltage is about 400V.
If you continue to increase the current, the voltage must not exceed an
average of 400V, if it does, adjust with R302.
7. After the adjustment, secure the potentiometers with varnish and reconnect
the HF unit.