EasyManua.ls Logo

EVS LSM-VIA

EVS LSM-VIA
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
How to Configure the Multi-Operator Mode
The configuration is done on each workstation from the Infrastructure settings of the LSM-VIA
configuration tool.
1. On each workstation, set the number of operators working with the same EVSserver thanks to the
Total Number of LSM-VIA Connected to the Server parameter. It must be the same on each
workstation.
2. On each workstation, each operator must select his/her operator number thanks to the Operator
Position parameter. It must therefore be different on each workstation.
3. On each workstation, each operator must select the recorder channels (s)he will work with thanks to
the Operator Recorders parameter.
The same recorders can be selected by several operators.
The remote buttons will automatically be mapped appropriately. For example, the selected recorders
B, C, E, L will be mapped on buttons A, B, C and D.
Examples
When 2 operators work with the same server, Operator #1 will configure his/her workstation as
follows:
Total Number of LSM-VIA Connected to the Server = 2
Operator Position = Operator 1
When 4 operators work with the same server,
Operator #3 will configure his/her workstation as follows:
Total Number of LSM-VIA Connected to the Server = 4
Operator Position = Operator 3
Operator #4 will configure his/her workstation as follows:
Total Number of LSM-VIA Connected to the Server = 4
Operator Position = Operator 4
Player Channels Distribution
According to the Total Number of LSM-VIA Connected to the Server and the Operator Position
parameters, the player channels will be split between the operators.
The number of available players on the server is divided by the total number of LSM-VIA connected
to the server. If there are more players than LSM-VIA (operators), the first operator(s) get(s) more
players.
The first operator receives the first player(s).
Examples:
4 operators in a 8IN/4OUTconfiguration: PGM1 is for Operator 1, PGM2 for Operator 2,...
USER MANUAL
LSM-VIA |3. Defining Channel Control| 25

Table of Contents

Other manuals for EVS LSM-VIA