Chapter 10: Replacing DC Power Supplies in Summit Family Switches
Summit Family Switches Hardware Installation Guide
354
Replacing a Summit 300 W DC Power Supply
Summit 300 W DC power supplies are compatible with the Summit X460 series non-PoE switches.
These switches have two bays for hot-swappable power supplies. In a redundant power configuration,
you can replace one Summit DC power supply without powering down the switch.
The following instructions apply to both the Model 10933 and 10934A 300 W DC power supplies.
You need the following tools and materials to replace a Summit 300 W DC power supply:
● #1 Phillips screwdriver
● Torque screwdriver and wrench or torque driver with attachments for tightening screws and nuts
● Thermal protective gloves (required for removal of a power supply)
WARNING!
Be sure to disconnect all power cables before you disconnect the chassis ground wire.
Removing the Power Supply
To remove an installed Summit 300 W DC power supply:
1 De-energize the DC circuit.
2 Disconnect the DC power cables as follows:
a Slide the cover off the terminal block.
b Loosen the screws that secure the cable terminals to the terminal block.
c Slide the wires out from under the captive washers.
3 Disconnect the ground wire as follows:
a Remove the screw that secures the ground wire to the power supply.
b Move the wire away from the power supply.
4 Push the latching tab to the left as you pull outward on the handle to disengage the power supply
internal connectors (see Figure 295 and Figure 296).