Appendix B: Technical Specifications
Summit Family Switches Hardware Installation Guide
500
Power Cord Requirements for AC-Powered Switches
and AC Power Supplies
Power cords used with AC-powered Summit family switches or Summit AC power supplies must meet
the following requirements:
The power cord must be agency-certified for the country of use.
The power cord must have an IEC320-C13 connector for connection to the switch or power supply.
The power cord must have an appropriately rated and approved wall plug applicable to the country
of installation.
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
2
) minimum; over 6 feet, the
minimum wire size is 16 AWG (1.0 mm
2
).
Console Connector Pinouts
This section provides connector pinouts for the console port and associated cables.
Table 109 describes the pinouts for a DB-9 console plug connector.
Figure 341 shows the pinouts for a 9-pin to 25-pin (RS-232) null-modem cable.
Table 109: Pinouts for the DB-9 Console Connector
Function
Pin
Number Direction
DCD (data carrier detect) 1 In
RXD (receive data) 2 In
TXD (transmit data) 3 Out
DTR (data terminal ready) 4 Out
GND (ground) 5 -
DSR (data set ready) 6 In
RTS (request to send) 7 Out
CTS (clear to send) 8 In