Appendix B: Technical Specifications
Summit Family Switches Hardware Installation Guide
438
International EMC certifications CISPR 22:2008 Class A (International Emissions for ITE
Equipment)
CISPR 24:2010 Class A (International Immunity for ITE
Equipment)
IEC 61000-4-2:2008/EN 61000-4-2:2009 (Electrostatic
Discharge, 8kV Contact, 15kV Air, Criteria A)
IEC 61000-4-3:2010/EN 61000-4-3:2006+A12008 +A2:2010
Radiated Immunity 20V/m, 80-960MHz, Criteria A
Radiated Immunity 10V/m, 960-2100MHz, Criteria A
Radiated Immunity 5V/m, 2100-2700MHz, Criteria A
IEC 61000-4-4:2011/EN 61000-4-4: 2004+A1: 2010 Transient
Burst,
Power AC, ± 2.0kV, Criteria A
Power DC, ± 2.0kV CM, 1kV DM, Criteria A
I/O Cables, ± 2.0kV for all I/O longer than 3m
IEC 61000-4-5:2005/EN 61000-4-5:2006 Surge, Test to
2/4kV, Level 3
AC Power, 1kV DM, 2kV CM, Criteria A
DC Power 1kV DM, 2kV CM, Criteria A
I/O 1kV L-G, Criteria A
IEC 61000-4-6:2008/EN 61000-4-6:2009 Conducted
Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A
IEC 61000-4-8:2009/EN 61000-4-8:2010 Magnetic Immunity,
Not applicable to Extreme's equipment
IEC 61000-4-11:2004/EN 61000-4-11:2004
Power Dips & Interruptions, >30%, 25 periods, Criteria C
Country-specific VCCI Class A (Japan Emissions)
ACMA (C-Tick) (Australia Emissions)
CCC Mark
KCC Mark, EMC Approval (Korea)
Telecom Standards
ETSI EN 300 386:2001 (EMC Telecommunications)
ETSI EN 300 019 (Environmental for Telecommunications)
MEF 9 complian
MEF 14 compliant
IEEE 802.3 Media Access
Standards
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000BASE-X
IEEE 802.3at PoE Plus
Environmental Data
Environmental standards EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
EN/ETSI 300 753 (1997-10) - Acoustic Noise
ASTM D3580 Random Vibration Unpackaged 1.5 G
Operating conditions Temperature: 0° C to 45° C (32° F to 113° F)
Humidity: 10% to 95% relative humidity, non-condensing
Altitude: 0 to 3,000 meters (9,850 feet)
Shock (half sine): 30 m/s
2
(3 G), 11 ms, 60 shocks
Random vibration: 3 to 500 Hz at 1.5 G rms
Table 84: Summit X440 Series Switch Technical Specifications (Continued)