·120·
Installation manual
CNC 8060
CNC 8065
2.
MACHINE PARAMETERS.
(REF: 1402)
Machine parameters for the axes and spindles.
JOG MODE. CONTINUOUS JOG.
JOGFEED
Feedrate in continuous jog.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 200000.0000 mm/min or degrees/min / from 0 to 7873.992 inch/min.
Default value: 1000.0000 mm/min or degrees/min / 39.37008 inch/min.
Associated variable: (V.)[ch].MPA.JOGFEED.xn
Parameter included in the JOG table.
This parameter sets the feedrate for movements in continuous jog mode.
JOGRAPFEED
Rapid feedrate in continuous jog.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 200000.0000 mm/min or degrees/min / from 0 to 7873.992 inch/min.
Default value: 10000.0000 mm/min or degrees/min / 393.70079 inch/min.
Associated variable: (V.)[ch].MPA.JOGRAPFEED.xn
Parameter included in the JOG table.
This parameter sets the rapid feedrate for movements in continuous jog mode.
MAXMANFEED
Maximum feedrate in continuous jog.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 200000.0000 mm/min or degrees/min / from 0 to 7873.992 inch/min.
Default value: 10000.0000 mm/min or degrees/min / 393.70079 inch/min.
Associated variable: (V.)[ch].MPA.MAXMANFEED.xn
Parameter included in the JOG table.
This parameter sets the maximum feedrate for movements in continuous jog mode.
MAXMANACC
Maximum acceleration in continuous JOG.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 1.0000 to 1000000.0000 mm/s² or degrees/s² / from 0.03937 to 3937.00787
inch/s².
Default value: 1000.0000 mm/s² or degrees/s² / 39.37008 inch/s².
Associated variable: (V.)[ch].MPA.MAXMANACC.xn
Parameter included in the JOG table.
This parameter sets the maximum acceleration for movements in continuous jog mode.
JOG MODE. INCREMENTAL JOG.
INCJOGDIST
Table for incremental jog distances.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
This parameter shows the table to define the axis movements in each position of the jog
selector switch. The table shows five parameters, one per each position of the operator panel.
INCJOGDIST1 Switch position ·1·.
INCJOGDIST2 Switch position ·10·.
INCJOGDIST3 Switch position ·100·.
INCJOGDIST4 Switch position ·1000·.
INCJOGDIST5 Switch position ·10000·.