·64·
Installation manual
CNC 8060
CNC 8065
2.
MACHINE PARAMETERS.
(REF: 1402)
General machine parameters.
VOLUMETRIC COMPENSATION TABLES.
VOLCOMP
Volumetric compensations tables.
This parameter shows the volumetric compensation table.
VOLCOMP n
Configuration of volumetric compensation tables.
This parameter shows the parameter table to define the volumetric compensations of the
system. Each table has the following machine parameters to configure it.
VCOMPAXIS1
VCOMPAXIS2
VCOMPAXIS3
Axis to be compensated.
Possible values: Any axes defined in AXISNAME.
Associated variable: (V.)MPG.VCOMPAXIS1[tbl] / (V.)MPG.VCOMPAXIS3[tbl]
Parameter included in the VOLCOMP table.
These parameters set the axes to be compensated with volumetric compensation. The axes
associated with the same compensation may belong to different channels and they may be
interchanged from one channel to another while the compensation is active. One axis may
be included in several compensations and these compensations may be active at the same
time.
VCOMPFILE
File containing volumetric compensation data.
Associated variable: (V.)MPG.VCOMPFILE[tbl]
Parameter included in the VOLCOMP table.
File containing the configuration tables for volumetric compensation. The tables cannot be
edited at the CNC and will be supplied by the company in charge of setting up the volumetric
compensation.
EXECUTION TIMES.
MINAENDW
Minimum duration of the AUXEND signal.
Possible values: From 0 to 65535 ms.
Default value: 10 ms.
Associated variable: (V.)MPG.MINAENDW
This parameter has the following meanings.
• This parameter sets the time that the AUXEND signal must stay active for the CNC to
consider it a valid signal. AUXEND is the synchronization signal that the PLC sends to
the CNC to indicate that the –M–, –S–, –T– functions have been executed.
• For –M– functions (which do not need synchronization), this parameter indicates the
duration of the MSTROBE signal.
• For –H– functions (which do not need synchronization), this parameter indicates the
duration of the HSTROBE signal.
The value assigned to this parameter must be equal to or greater than the PLC's input
frequency (LOOPTIME x PRGFREQ).
VOLCOMP
VCOMPAXIS1
VCOMPAXIS2
VCOMPAXIS3
Axes to be compensated.
VCOMPFILE File containing volumetric compensation data.