·66·
Installation manual
CNC 8060
CNC 8065
2.
MACHINE PARAMETERS.
(REF: 1402)
General machine parameters.
DIMOD n
Base index of the digital input modules.
Possible values: From 0 to 1009.
Default value: The first valid value.
Associated variable: (V.)MPG.DIMODADDR[nb]
Parameter included in the DIMODADDR table.
This parameter sets the base index from which the digital inputs of the module are numbered.
Remote modules (for bus CAN with CANfagor protocol).
The values of the base index must be comply with the formula "16n + 1" (i.e. 1, 17, 33, etc.).
If an invalid base index is entered, it assumes the nearest previous valid one. The base
indexes may follow any order, they do not have to be sequential.
Remote modules (for bus CAN with CANopen protocol).
The values of the base index must be comply with the formula "8n + 1" (i.e. 1, 9, 17, 25, etc.).
If an invalid base index is entered, it assumes the nearest previous valid one. The base
indexes may follow any order, they do not have to be sequential.
The double input/output module must be assigned two base indexes for the inputs and two
base indexes for the outputs; one for each board;
NDOMOD
Total number of digital output modules.
Possible values: From 0 to 64.
Default value: 0 (no numbering is defined).
Associated variable: (V.)MPG.NDOMOD
This parameter indicates the number of these modules connected to the same CAN bus.
In remote modules with CANopen protocol each double module of digital inputs and outputs
counts as two.
After defining this value, it is possible to set the numbering of the digital outputs of each
module. If this parameter is not set, the CNC numbers the digital outputs sequentially
according to the order of the modules in the bus.
DOMODADDR
Table of digital output modules.
This parameter shows the list of digital output modules connected to the same bus CAN.
When inserting a new module, the CNC will assign the numbering of the table to the first
modules and the next valid base index after the highest one assigned until then to the last
module.
DOMOD n
Base index of the digital output modules.
Possible values: From 0 to 1009.
Default value: The first valid value.
Associated variable: (V.)MPG.DOMODADDR[nb]
Parameter included in the DOMODADDR table.
This parameter sets the base index from which the digital outputs of the module are
numbered.
Remote modules (for bus CAN with CANfagor protocol).
The values of the base index must be comply with the formula "16n + 1" (i.e. 1, 17, 33, etc.).
If an invalid base index is entered, it assumes the nearest previous valid one. The base
indexes may follow any order, they do not have to be sequential.
Remote modules (for bus CAN with CANopen protocol).
The values of the base index must be comply with the formula "8n + 1" (i.e. 1, 9, 17, 25, etc.).
If an invalid base index is entered, it assumes the nearest previous valid one. The base
indexes may follow any order, they do not have to be sequential.