トラブルシューティング - TROUBLESHOOTING
Troubleshooting table
Problem Possible cause Possible solution
It is not possible to activate the display or the
power-assisted pedalling system.
The battery pack has malfunction, despite being
fully charged.
Press the white push-button on the battery
pack to check whether it is switched on. The
battery pack charge level indicator LEDs
should switch on. If they do not, the battery
pack may be defective.
Battery pack overheated. Wait until the battery pack has cooled down.
Battery pack not installed correctly.
Remove the battery pack and attempt to
reinsert it into its coupling. Make sure that
it is positioned correctly.
Battery pack discharged.
Recharge the battery pack using the dedicated
battery charger.
Electrical contacts
connector
damaged.
on battery pack and/or
Make sure that all the contacts are clean. If
necessary, clean them using a soft, dry
cloth.
Display not mounted correctly on its support.
Remove the display from the support and
reposition it. Make sure that it has been
inserted correctly.
Display and/or support contacts damaged.
Make sure that all the contacts are clean. If
necessary, clean them using a soft, dry
cloth.
Connector not inserted correctly into the battery pack.
Insert the connector correctly into the battery
pack contact.
The display does not provide any data, even
though the bicycle is in motion.
Light power supply cables on connected correctly.
Check the position of the contact on the
rear wheel spokes; in particular, the distance
from the speed sensor must be between 5
mm and 17 mm.
The bicycle lights (if fitted) do not switch on. Cavi delle le luci non correttamente connesse.
Check the cables and the electrical plugs
and connect them correctly.
The display indicates an error code. A system error is present. Consult the following table.
108