If you experience any problems using your Brose Drive System, first check the items listed in the following table. In many cases, you can already remedy
this yourself.
Symptom Possible cause Solution
Display unit and/or Brose Drive System cannot
be activated.
Battery not correctly clicked into the holder.
If possible, remove the battery and reinsert it.
Pay attention that it is in the proper position.
Battery not charged up.
Charge up fully using the supplied battery char-
ger.
Battery contacts and/or holder soiled.
Make sure all contacts are clean. If necessary,
clean with a soft, dry cloth.
Display unit not correctly connected.
Check the plug connection of the display unit.
Pay attention that is it properly connected.
Display unit contacts and/or holder soiled.
Make sure all contacts are clean. If necessary,
clean with a soft, dry cloth.
Plug connections on the drive unit not
correctly inserted.
Check cabling and connections and connect
them correctly if necessary.
Display unit does not provide trip data even
though the e-bike is in motion.
The sensor and magnet may not be positioned
correctly.
Check the magnet assembling in the hub and
check the sensor assembling in the frame. The
sensor should be positioned vertically.
Bicycle lighting cannot be activated. Lighting cable incorrectly connected.
Check cabling and connections and connect
them correctly if necessary.
Display unit indicates an error in the multifunc-
tion panel.
There is an active error in the system. Please note the following table.