Altitude: < 2000 m (6561 ft)
IP rating of the scanner when
in an upright position:
IP54
*
For extended operation at 55°C (131°F): Cool down the accessory thermal cover to -15°C (5°F )or
colder and store the scanner below 25°C (77°F). Prepare scanner with thermal cover and without any
other accessory. Turn it on. Scanning is possible for 1 hour. Then turn the scanner off to cool it down to
below 25°C (77°F) for 2 hours before scanning again with a cooled thermal cover.
Scanner Dimensions
Figure 9-1 Scanner Dimensions
All dimensions are in mm.
FARO
®
Focus Premium Laser Scanner User Manual
Chapter 9: Technical Data
FARO Focus Premium (March 2022) Page135of157