Festo — EMCS-ST — 2021-03b
Index.
Subindex
Name Description Data type
(length)
Access
1)
U = User
M = Maintenance
personnel
S = Specialist
U M S
0x0127.0
(295.0)
Number of
cycles since
reset
3)
Number (dec) of completed
cycles of the drive unit since the
last reset
–
UInteger32
(4 bytes)
R R R
0x0128.0
(296.0)
Mileage total
3)
Mileage of the drive unit since
delivery
Linear drive systems
– Length value [km] x 0.000001
Rotary drive systems
–
Rotation value [r] x 0.001
UInteger32
(4 bytes)
R R R
0x0129.0
(297.0)
Mileage since
reset
3)
Mileage of the drive unit since
the last reset
Linear drive systems
– Length value [km] x 0.000001
Rotary drive systems
–
Rotation value [r] x 0.001
UInteger32
(4 bytes)
R R R
0x012A.0
(298.0)
Reset cycle &
mileage
Reset cycle and mileage counter
–
true: reset counter
–
false: do not reset counter
–
BooleanT
(1 bytes)
W W W
Saving parameters (from firmware version v19.0.4.107_release)
0x0109.0
(265.0)
Auto Store
Active
Control command for acti-
vating automatic and permanent
saving of parameters in the flash
memory
è
Tab. 25 Data storage
parameters
–
true: automatic saving acti-
vated (default)
– false: automatic saving deac-
tivated. Saving can be con-
trolled via the parameter
0x010B.0 Store parameters.
BooleanT
(1 bytes)
– R/W R/W
0x010A.0
(266.0)
Number Of
Storage Oper-
ations
4)
Information about the number of
permanent storage processes in
the flash memory
UInteger32
(4 bytes)
– R R