6.3.3 Wall Mounting
1
Adapter plate
Fig. 14 Wall Mounting
1. Mount adapter plates (e.g.2 x M3).
Hole patterns and dimensions è 15.3 Hole patterns.
2. Hang the sensor in the adapter plates and press until the fastening slide clips in.
6.4 Use sensor module without control module
The supply pressure can be fed from the left and the right-hand side.
1
Connection for supply pressure
Fig. 15 Attach the sensor modules
1. Mount the fitting (thread M7) to the supply pressure port.
Thread length: max. 5.5mm
2. Seal the exposed connection with a blanking plug.
SW: 3mm
Assembly
21Festo — SOPA — 2020-04