As an alternative a LV/C (Limited Voltage/Current) power source with one of the following properties
can be used:
This device shall be used with a suitable isolating source such that the maximum open circuit
voltage potential available to the product is not more than 30VDC and the current is limited to a
value not exceeding 8amperes measured after 1minute of operation.
This device shall be used with a suitable isolating source in conjunction with a fuse in accordance
with UL248. The fuse shall be rated max. 3.3A and be installed in the 30VDC power supply to
the device in order to limit the available current.
3 Further information
Accessories èwww.festo.com/catalogue.
Spare parts èwww.festo.com/spareparts.
4 Service
Contact your regional Festo contact person if you have technical questions èwww.festo.com.