7.2.2 PIN allocation and sensor module circuit diagrams................................................ 24
8 Commissioning.............................................................................................................25
8.1 Displaying parameters (INFO/SHOW mode).................................................................. 25
8.2 Menu structure (EDIT mode)..........................................................................................27
8.3 Setting the switching characteristics of the binary signals (EDIT mode)........................ 28
8.4 Setting analogue output with…-PNLK-A (EDIT mode).................................................. 29
8.5 Setting analogue output with…-PNLK-VB (EDIT mode)................................................29
8.6 Teaching the switching points (TEACH mode)................................................................30
8.7 Setting the spurious pulse suppression (EDIT mode).................................................... 30
8.8 Switch off display (EDIT mode)...................................................................................... 31
8.9 Changeover of binary output OutA (EDIT mode)............................................................ 31
8.10 Setting the allocation of the switching output at Pin 2 (EDIT mode).............................. 31
8.11 Setting the allocation of the switching output at Pin 4 (EDIT mode).............................. 32
8.12 Setting security code (EDIT mode).................................................................................32
8.13 Replicating parameters (EDIT mode)............................................................................. 32
9 IO-Link interface description........................................................................................33
9.1 General information, IO-Link..........................................................................................33
9.2 Identification parameters.............................................................................................. 34
9.3 IO-Link default parameters............................................................................................ 35
9.4 IO-Link default commands.............................................................................................36
9.5 Smart sensor profile parameters................................................................................... 36
9.6 Device-specific parameters............................................................................................39
9.7 IO-Link teach-in............................................................................................................. 40
9.8 Block parameterisation................................................................................................. 42
9.8.1 Block parameterisation for Distance monitoring SSC1 (OutA).................................42
9.8.2 Block parameterisation for Distance monitoring SSC2 (OutB)................................ 43
9.8.3 Block parameterisation for Supply pressure monitoringSSC3 (OutC)..................... 43
9.8.4 Block parameterisation for analogue output.......................................................... 43
9.9 Process data IN..............................................................................................................43
9.10 Correction factors.......................................................................................................... 44
9.11 Diagnostics IO-Link........................................................................................................44
9.11.1 Status messages.................................................................................................... 44
9.11.2 Diagnostic levels.................................................................................................... 44
10 Operation and use........................................................................................................ 45
10.1 Notes on operation........................................................................................................45
10.2 Restoring Factory Settings (Restore)............................................................................. 45
10.3 Using the differential pressure regulator....................................................................... 46
11 Maintenance and Care..................................................................................................46
12 Malfunctions................................................................................................................ 46
12.1 Error messages..............................................................................................................46