The Panda Generator
Seite/Page 50 - Kaptitel/Chapter A: The Panda Generator 19.8.14
Fuel solenoid valve
The fuel solenoid valve opens
automatically if „START“ is pressed on the
remote control panel“. The solenoid closes,
if the generator is switched to „OFF“
position. It takes a few seconds before the
generator stops. If the generator does not
start or does not run smoothly (i.e.
stutters), or does not attain full speed, then
the cause is fore-mostly the solenoid.
1) Fuel solenoid valve
2) Ventilation screw solenoid valve
3) Magnetic coil
Fig. A.16: Fuel solenoid valve
Injection nozzles
If the engine does not start after the
ventilation, the fuel injection lines must be
deaerated individually.
Fig. A.17: Injection nozzles
Glow plugs
The glow plugs serve the pre-chamber for
the heating with cold start. The heat-treat
fixture must be operated, if the
temperature of the generator is under
16°C. This is practically with each start the
case. The heat-treat fixture may be held
down also during start and favoured the
starting procedure.
Fig. A.18: Glow plugs