I&J7000 Series Operating Manual
Section 6: Point Type & Function Details
Part # 561978B
Rev. H May 04
3.1.4. Line SP (Line Speed)
To use group edit to increase all of the line speed commands in memory address range 1
– 200 by 20 %:
Press the MENU 1 key, then 1 to select Group
Edit. The display will prompt the user to enter the
starting memory address of the group to edit
(From) and the ending number of the group to
edit (To).
GROUP EDIT
FROM:1
TO:1
(1 <-> 1000)
Type 1 then press ENTER to register 1 in From.
Type 200 then press ENTER to register 200 in
To.
GROUP EDIT 1-200
1.Copy 4.Line SP
2.Delete 5.Dispen.TM
3.Move 6.Offset
The Group Edit menu will then appear, allowing
the user to select from which function to apply to
the range of points.
Press 4 to select Line SP.
GROUP LINE SP
Multiple Value:
The display will prompt the user to type the
Multiple Value to be applied to the line speeds.
For example, a value of 1.2 will increase all
speeds by 20%. A value of 0.8 will decrease all
speeds by 20%.
Type 1.2 and press ENTER to select a multiplier
of 1.2.
GROUP LINE SP
Multiple Value:1.2
1.Yes 2.No
SELECT:
The display will now prompt the user to confirm
the change. Press 1 to select Yes.
All of the line speed instructions in the select
range of points will now be multiplied by 1.2.