I&J7000 Series Operating Manual
Section 7: Specifications
Part # 561978B
Rev. H May 04
- Page 76 -
© 2003 I&J Fisnar Inc.
1. Error Messages
1.1. Points Closed Error
This message occurs when two adjacent line or arc points are registered at exactly the
same XYZ location.
Do not register two line points, one after the other, at exactly the same XYZ location.
1.2. Need Line Start Point
An attempt was made to register a Line Passing point, an Arc point or a Line End point
without first registering a Line Start point.
Register a Line Start point before registering a Line Passing, an Arc point or a Line End
point.
1.3. Need Step & Repeat
The Expand Step & Repeat command was given but there is no Step & Repeat instruction
currently in the display. Move to the Step & Repeat function you want to expand before
selecting Expand Step & Repeat.
1.4. Unlock Program
An attempt was made to edit a program in Teach mode which is locked. The program can
not be edited until it is unlocked. Unlock the program in Menu 1, Utility Menu, Lock
Program.