EasyManua.ls Logo

FLENDER B3 A Series - Oil Level Indicator

FLENDER B3 A Series
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
① Heating element ② Temperature monitor
Figure 3-10 Heating on type B3.. gear units
Heating element control
Heating elements can be controlled by a temperature monitor. The temperature monitor
provides a signal to be ampli󹪝ed when the minimum and maximum temperatures are reached.
Further information
Further information about the position of the mounted components and a detailed illustration
of the gear unit can be found in the dimension drawing in the complete documentation for the
gear unit.
Further information about heating elements can be found in the separate data sheet, in the list
of equipment and in the heating element operating instructions in the complete documentation
for the gear unit.
Further information about the temperature monitor (such as control instructions) can be found
in the temperature monitor operating instructions in the complete documentation for the gear
unit.
3.13 Oil level indicator
The following components for visual monitoring of the oil level can be mounted on the gear unit:
• Oil sight glass
• Oil level indicator
• Oil dipstick
Check the oil level when the gear unit is stationary and with the oil in a cool state.
Further information
Further information about the oil level indicator and checking the oil can be found in the
operating instructions BA 7300 in the complete documentation for the gear unit.
Further information, a detailed illustration of the gear unit and the position of the mounted
components can be found in the dimension drawing in the complete documentation for the
gear unit.
Description
3.13 Oil level indicator
Assembly and operating instructions A5051en
38 Edition 06/2020

Table of Contents