5.9.4 Connecting the oil-level monitoring system
Procedure
To connect the oil-level monitoring system to the gear unit, proceed as follows:
1. Ensure that the lling level limit switch connection is not damaged.
2. Electrically connect the lling level limit switch.
3. Connect the signal so that for the "oil level too low" signal, the drive motor cannot start and
an alarm is output.
Bypass this signal in operation.
Further information
Additional information about the oil-level monitoring system can be found in the operating
instructions for the oil-level monitoring system components provided in the complete gear unit
documentation.
You can nd technical data in the separate data sheet and in the equipment list in the complete
gear unit documentation.
5.9.5 Connecting the Pt 100 resistance thermometer
Procedure
To connect the Pt 100 resistance thermometer, proceed as follows:
1. Check that the Pt 100 resistance thermometer connection is not damaged.
2. Install the electrical wiring between the Pt 100 resistance thermometer and the evaluation
unit. The customer is responsible for providing the evaluation unit.
Further information
Further information about the Pt 100 resistance thermometer can be found in the Pt 100
resistance thermometer operating instructions in the complete documentation for the gear unit.
5.9.6 Connecting a speed encoder
Procedure
To connect the air-oil cooler to the gear unit, proceed as follows:
1. Ensure that the speed encoder connection is not damaged.
2. Electrically connect the speed encoder.
Assembly
5.9 Connecting components
Assembly and operating instructions A5051en
Edition 06/2020 89