Possible faults Causes Possible remedies
Contamination indica‐
tor of the double
change-over filter trig‐
gers an alarm
Double change-over filter clogged
Changeover the double change-over filter corresponding
to the separate operating instructions
Clean the filter element
Water in the oil Oil supply system or cooling coil de‐
fective
Check the oil supply system or cooling coil
Replace defective components if necessary
Read the operating instructions for the oil supply system
Engine room fan is blowing cold air
onto gear unit: Water condenses
Install suitable thermal insulation to protect gear unit
housing
Close the air outlet or change the direction of the air outlet
using structural measures.
Climatic conditions
Contact Customer Services
Use wet-air filter if necessary
Oil foams in the oil sump
Take test tube sample to examine oil condition for water
penetration
Have the oil examined by a chemical lab
Maintenance
8.4 Possible faults
REDUREX Gear unit 5200en
Operating Instructions 03/2019 103