8.3.6 Measuring the vibration levels of the rolling-contact bearings
Procedure
Proceed as follows to measure the vibration levels of the rolling-contact bearings:
1. Document the measurement results.
2. Compare the measured values with the comparison values that were documented when
commissioning the gear unit.
3. Replace defective rolling-contact bearings.
4. Archive the report together with these instructions.
Further information
You can find additional information on measuring the vibration levels at rolling-contact bearings
in the operating instructions of the measurement sensor provided in the complete gear unit
documentation.
8.3.7 Measuring the temperature at the rolling-contact bearings
Procedure
Proceed as follows to measure the temperature at the rolling-contact bearings:
1. Measure the temperature at the rolling-contact bearings.
2. Document the measurement results.
3. Compare the measured values with the comparison values that were documented when
commissioning the gear unit.
4. Archive the report together with these instructions.
5. Have Customer Services replace defective rolling-contact bearings.
Further information
Further information about measuring the temperature at the rolling-contact bearings can be
found in the Pt 100 resistance thermometer operating instructions in the complete
documentation for the gear unit.
Maintenance
8.3 Maintenance and service work