15 Data logger
FLUXUS WD 15.1 Configuration of the data logger
119
UMFLUXUS_WDV1-3EN, 2018-07-16
Event-based starting time
If it is necessary to start the storing of measured values at
a particular event, select Event-based as starting time.
The event is signalized via an input or the event trigger. All
configured inputs and event triggers are displayed in the
scroll list.
Select the input or the event trigger through which the
event is to be signalized.
•Press ENTER.
The storage rate indicates the interval how often the mea-
sured values are transmitted or stored.
Select in the scroll list a storage rate intended to store the measured values in case the event is not triggered.
Press ENTER.
•Select Off if no measured values are to be stored, as long as the event is not triggered.
Press ENTER.
Select in the scroll list a storage rate intended to store the measured values in case the event is triggered.
Press ENTER.
Enter the time interval for the measured values to be stored before reaching the event.
Press ENTER.
Enter the time interval for the measured values to be stored if the event is no longer active.
Press ENTER.
Storage rate FastFood
The Storage rate FastF is the storage rate at which the measured values are stored in the FastFood mode.
Select the menu item Configuration in the program branch Special functions\Data logger.
Press ENTER until the menu item Storage rate FastF is displayed.
Enter the value for the Storage rate FastF in ms.
Press ENTER.
Special functions
Data logger
Configuration
Logger channels
Start storing
Event-based
Storage rate w/o trig.
Storage rate (trig.)
Buffer time 
Buffer time 
see annex A, p. 162
Special functions\
Data logger\
Configuration
\Start storing\Event-based
Special functions\
Data logger\
Configuration
\Start storing\Event-based\
Storage rate w/o trig.
Special functions\
Data logger\Configuration
\Start storing\Event-based\Storage rate (trig.)
Special functions\
Data logger\Configuration
\Start storing\Event-based\Buffer time ->П
Special functions\
Data logger\Configuration
\Start storing\Event-based\Buffer time П->
Special functions\
Data logger\Configuration
\Storage rate FastF