143
Server Tree Structure:
The server must have the tree structure specic to the WebdynSunPM product. The concentrator
proposes one by default but it can be customised. This architecture must exist on the server before the
rst connection because the concentrator does not create the directories.
Below the root directory, the server must have the following directories:
NAME RIGHTS DESCRIPTION
/CONFIG Read/Write Contains cong les. The concentrator conguration uploaded by
the concentrator is in the following format: <uid>_cong.ini
The connection interface conguration uploaded by the
concentrator is in the following format: <uid>_daq.csv
The connection schedule conguration uploaded by the
concentrator is in the following format: <uid>_var.ini
The connection schedule conguration uploaded by the
concentrator is in the following format: <uid>_scl.ini
/DEF Read/Write Contains the denition les. The denition le has the following
format: <uid>_<interface>_<comment>.csv
/SCRIPT Read/Write Contains the script les. The script le has the following format:
<comment>.lua
/CERT Read/Write Contains the certicates. The certicate has the following format:
<comment>.pem
/DATA Write Contains the collected data. The data le name is in the following
format: <uid>_<interface>_<timestamp>.csv.gz
/CMD Read/Write/
Delete
Contains the commands. The command le has the following
format: <uid>_cmd.csv
/ALARM Write Contains the alarms. The alarm le name is in the following format:
<uid>_AL_<timestamp>.csv.gz
/LOG Write Contains the log and debug les. The log le has the following
format: <uid>_LOG_<timestamp>.log.gz
The debug le has the following format: <uid>_
SYSTEME_<timestamp>.tar.gz
/BIN Read Contains the update les. The concentrator update has the
following format: wgapp_<version>.spm