A “Power OFF” alarm is sent following a power cut of at least 10 seconds and a “Power ON” alarm is sent
once the power supply has returned for at least 1 minute. The other alarms have no timers and are sent
as soon as the concentrator detects them.
The alarm le on the server has the following format:
<uid>_AL_<timestamp>.csv.gz
Where:
<uid>: Concentrator identier.
<timestamp>: The timestamp format is “YYMMDD_HHMMSS” so that an alphabetical sort of
the directory gives the chronological order.
The GATEWAY type alarm le format is the following:
datetime_1;GATEWAY;info_1
datetime_2;GATEWAY;info_2
...
datetime_Y;GATEWAY;info_X
Colour code:
Black: xed text.
Blue: device-specic information or data.
Where:
datetime_Y: alarm timestamp at trigger point Y. For the format, see variables FTP_
EuroDateFormat, FTP2_EuroDateFormat, HTTP_EuroDateFormat and HTTP2_EuroDateFormat
in section 3.2.2.5: “Servers”.
info_X: Information on alarm X.