contact@webdyn.com | webdyn.com
V2.05 subject to changes | Webdyn © by Flexitron Group
Each analog input can be software congured to 0-10V or 4-20mA.
The concentrators analog/digital converters (CAN) have 12 bit resolution making possible in:
• 0-10 V mode: to have .578 mV resolution.
• 4-20 mA mode: to have 5.578 µV resolution.
To connect, power off the concentrator and the 0-10V or 4-20mA sensor. Take into account the
wiring information provided by the sensor manufacturer.
Do not apply a voltage higher than 12V or a current higher than 24mA to the analog inputs.
The voltage available for the sensors on the terminal block is the same as the power supply block
voltage used to power the concentrator. The maximum power available for all the sensors must not
exceed 7 watts.