10
Keylock enable
11
Keylock disable
12
Dynamic Start
13
Dynamic Reset
14-23
Not used
24
Basic peak enable
25
Basic peak disable
26
Hold enable
27
Hold disable
40027
R
2
Commands status
0
None
1
Command is processing…
2
Command is successfully.
3
Command failed.
40029
R/W
12
Reserve
40041
R
2
Status of Inputs
Bit
Definition
B0
Input-1
0 Passive
1 Active
B1
Input-2
B2
Input-3
B3
Input-4
40043
R/W
2
Status of Outputs
B0
Output-1
0 Passive
1 Active
B1
Output-2
B2
Output-3
B3
Output-4
B4
Output-5
40045
R/W
2
Setpoint 1 (High)
40047
R/W
2
Setpoint 2 (High)
40049
R/W
2
Setpoint 3 (High)
40051
R/W
2
Setpoint 4 (High)
40053
R/W
2
Setpoint 5 (High)
40055
R/W
2
Not used
40057
R/W
2
Setpoint 1Low
Only available for Threshold and Window feature.
Refer to sub-block 36-, page 59 to see the availabilities.
40059
R/W
2
Setpoint 2Low
40061
R/W
2
Setpoint 3Low
40063
R/W
2
Setpoint 4Low
40065
R/W
2
Setpoint 5Low
40127
R/W
2
Dynamic filter
Refer to parameter [332] on page 57
40129
R/W
2
Digital filter
Dec
Description
0
No
1
Very Low
2
Low
3
Medium
4
High
5
Very High
40131
R/W
2
Power on zero
0
Disable
1
± 2%
2
± 2%LK
3
± %10
4
+ %15, - %5
5
± %20
40133
R/W
2
Zeroing Range
0
Disable
1
± 2%
2
± 3%

Table of Contents