10-1
Chapter 10
SC300 Oscilloscope Calibration Option
Contents Page
Introduction .......................................................................................................... 10-3
SC300 Oscilloscope Calibration Option Specifications ...................................... 10-4
Volt Function Specifications ........................................................................... 10-4
Edge Function Specifications .......................................................................... 10-5
Leveled Sine Wave Function Specifications ................................................... 10-5
Time Marker Function Specifications ............................................................. 10-6
Wave Generator Specifications ....................................................................... 10-6
Trigger Signal Specifications for the Time Marker Function ......................... 10-6
Trigger Signal Specifications for the Edge Function ...................................... 10-6
Oscilloscope Connections .................................................................................... 10-7
Start the Oscilloscope Calibration Option ........................................................... 10-8
The Output Signal............................................................................................ 10-8
Adjust the Output Signal ................................................................................. 10-9
Key in a Value ............................................................................................. 10-9
Adjust Values with the Rotary Knob .......................................................... 10-9
Use and ..................................................................................... 10-10
Reset the Oscilloscope Option ......................................................................... 10-10
Calibrate the Voltage Amplitude on an Oscilloscope .......................................... 10-11
The Volt Function............................................................................................ 10-11
The V/DIV Menu ............................................................................................ 10-12
Shortcuts to Set the Voltage Amplitude .......................................................... 10-13
Amplitude Calibration Procedure for an Oscilloscope .................................... 10-13
Calibrate the Pulse and Frequency Response on an Oscilloscope ....................... 10-14
The Edge Function .......................................................................................... 10-14
Pulse Response Calibration Procedure for an Oscilloscope ............................ 10-15
The Leveled Sine Wave Function ................................................................... 10-16
Shortcuts to Set the Frequency and Voltage .................................................... 10-17
The MORE OPTIONS Menu .......................................................................... 10-18
Sweep through a Frequency Range ................................................................. 10-19
Frequency Response Calibration Procedure for an Oscilloscope .................... 10-20
Calibrate the Time Base of an Oscilloscope ........................................................ 10-22
The Time Marker Function.............................................................................. 10-22