SC300 Oscilloscope Calibration Option
SC300 Oscilloscope Calibration Option Specifications 10
10-5
Edge Function Specifications
Edge Characteristics into 50 Ω
1-Year Absolute Uncertainty, tcal ±
5°C
Amplitude
Range (p-p)
4.5 mV to 2.75 V
±(2 % of output + 200 μV)
Resolution 4 digits
Adjustment Range
±10 % around each sequence value (shown
below)
Sequence
5 mV, 10 mV, 25 mV, 50 mV, 100 mV, 250 mV,
500 mV, 1 V, 2.5 V
Other Edge Characteristics
Frequency Range 1 kHz to 1 MHz
±(25 ppm of setting + 15 mHz)
Rise Time
< 400 ps
Leading Edge Aberrations within 10 ns
<(3% of output + 2 mV)
10 to 30 ns
<(1% of output + 2 mV)
after 30 ns
<(0.5% of output + 2 mV)
Typical Duty Cycle 45 % to 55 %
Leveled Sine Wave Function Specifications
Leveled Sine Wave Frequency Range
Characteristics into 50 Ω
50 kHz Reference 50 kHz to 100 MHz
100 to 300 MHz
[1]
Amplitude Characteristics
Range (p-p) 5 mV to 5.5 V
[1]
Resolution
<100 mV: 3 digits
100 mV: 4 digits
Adjustment Range continuously adjustable
1-Year Absolute Uncertainty, tcal
± 5 °C
±(2% of output + 200 μV) ±(3.5% of output + 300 μV) ± (4% of output + 300 μV)
Flatness (relative to 50 kHz)
not applicable
±(1.5% of output + 100 μV) ± (2.0% of output +
100 μV)
Short-term Stability
1%
[2]
Frequency Characteristics
Resolution 10 Hz 10 kHz
[3]
10 kHz
1-Year Absolute Uncertainty, tcal
± 5 °C
±(25 ppm + 15 mHz) ±25 ppm
[4]
± 25 ppm
Distortion Characteristics
2nd Harmonic
-35 dBc
3rd and Higher Harmonics
-40 dBc
[1] Extended frequency range to 350 MHz is provided, but flatness is not specified. Amplitude is limited to 3 V for frequencies
above 250 MHz.
[2] Within one hour after reference amplitude setting, provided temperature varies no more than ± 5°C.
[3] At frequencies below 120 kHz, the resolution is 10 Hz. For frequencies between 120 kHz and 999.9 kHz, the resolution is
100 Hz.
[4] ±(25 ppm + 15 mHz) for frequencies of 1 MHz and below.