Specifications
Miscellaneous 2
2-13
Power
Fluke 190-xx4, -50x: Rechargeable Li-ion Battery (model BP291):
Operating Time ................................................... up to 7 hours (Low Intensity)
Charging Time ..................................................... 5 hours
Capacity/Voltage ................................................. 52 Wh / 10.8 V
Fluke 190-062, -102, -202: Rechargeable Li-ion Battery (model BP290):
Operating Time .................................................... up to 4 hours (Low Intensity)
Charging Time ..................................................... 2.5 hours
Capacity/Voltage ................................................. 26 Wh / 10.8 V
Rechargeable Li-ion Battery (model BP 290 and BP291):
Life Time (>80 % capacity) .................................. 300 x charge/discharge
Allowable ambient temperature
during charging ....................................................... 0 °C to 40 °C (32 °F to 104 °F)
Auto power down time
(battery saving) ................................................... 5 min, 30 min or disabled
Power Adapter BC190:
BC190/801 European line plug 230 V ±10 %
BC190/813 North American line plug 120 V ±10 %
BC190/804 United Kingdom line plug 230 V ±10 %
BC190/806 Japanese line plug 100 V ±10 %
BC190/807 Australian line plug 230 V ±10 %
BC190/808 Universal switchable adapter 115 V ±10 % or 230 V ±10 %, with plug EN60320-2.2G
BC190/820 Universal adapter 100...240 V ±10 %, with plug EN60320-2.2G
Line Frequency ........................................................ 50 Hz and 60 Hz
Probe Calibration
Manual pulse adjustment and automatic DC adjustment with probe check
Generator Output .................................................... 1.225 Vpp / 500 Hz square wave
Internal Memory
Number of Scope Memories .................................... up to 30 (varies according to version)
Each memory can contain 2/4 waveforms plus corresponding setups
Number of Recorder Memories ............................... 10
Each memory can contain:
2/4 channel input TrendPlot
2/4 channel input Scope Record
100 2/4 channel input Scope screens (Replay)
Number of Screen Image memories ....................... 9
Each memory can contain one screen image
External Memory
USB stick, 2GB max
Mechanical
Size ......................................................................... 265 mm x 190 mm x 70 mm (10.5 in x 7.5 in x 2.8 in)
Weight
Fluke 190-xx4 ...................................................... 2.2 kg (4.8 lb) including battery
Fluke 190-5xx ...................................................... 2.2 kg (4.8 lb) including battery
Fluke 190-xx2 ...................................................... 2.1 kg (4.6 lb) including battery
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Fluke ScopeMeter 190 II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke ScopeMeter 190 II Series and is the answer not in the manual?

Fluke ScopeMeter 190 II Series Specifications

General IconGeneral
BrandFluke
ModelScopeMeter 190 II Series
CategoryTest Equipment
LanguageEnglish

Related product manuals