Page #26 background imageLoading...
Page #26 background image
Specifications
Automatic Scope Measurements 2
2-5
Edge Trigger
Screen Update ........................................................ Free Run, On Trigger, Single Shot
Source ..................................................................... A, B, C, D, EXT (190-xx2)
Slope ....................................................................... Positive, Negative, Dual
Trigger Level Control Range ................................... ±4 divisions
Trigger Sensitivity
DC to 5 MHz at >5 mV/div ................................... 0.5 division
DC to 5 MHz at 2 mV/div
and 5 mV/div ....................................................... 1 division
500 MHz (Fluke 190-50x) .................................... 1 division
200 MHz (Fluke 190-2xx) .................................... 1 division
100 MHz (Fluke 190-1xx) .................................... 1 division
60 MHz (Fluke 190-062)...................................... 1 division
Isolated External Trigger (190-xx2)
Bandwidth ................................................................ 10 kHz
Modes ...................................................................... Automatic, Edge
Trigger Levels (DC to 10 kHz) ................................. 120 mV, 1.2 V
Video Trigger
Standards ................................................................ PAL, PAL+, NTSC, SECAM, Non-interlaced
Modes ...................................................................... Lines, Line Select, Field 1 or Field 2
Source ..................................................................... A
Polarity .................................................................... Positive, Negative
Sensitivity ................................................................ 0.7 division sync level
Pulse Width Trigger
Screen Update ........................................................ On Trigger, Single Shot
Trigger Conditions ................................................... <T, >T, =T (±10 %), T(±10 %)
Source ..................................................................... A
Polarity .................................................................... Positive or negative pulse
Pulse Time Adjustment Range ................................ 0.01 div. to 655 div.
with a minimum of 300 ns (<T, >T) or 500 ns (=T, T), a maximum of
10 s, and a resolution of 0.01 div. with a minimum of 50 ns
Continuous Auto Set
Autoranging attenuators and time base, automatic Connect-and-View triggering with automatic source selection.
Modes
Normal ................................................................. 15 Hz to max. bandwidth
Low Frequency .................................................... 1 Hz to max. bandwidth
Minimum Amplitude A, B, C, D
DC to 1 MHz ........................................................ 10 mV
1 MHz to max. bandwidth .................................... 20 mV
Automatic Capturing Scope Screens
Capacity .................................................................. 100 Scope Screens
For viewing screens, see Replay function.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Fluke ScopeMeter 190 II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke ScopeMeter 190 II Series and is the answer not in the manual?

Fluke ScopeMeter 190 II Series Specifications

General IconGeneral
BrandFluke
ModelScopeMeter 190 II Series
CategoryTest Equipment
LanguageEnglish

Related product manuals