Fluke ScopeMeter 190 II Series - Pass - Fail Testing; Analyzing Waveforms

Fluke ScopeMeter 190 II Series
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parts List
Final Assembly Parts 3
3-5
Table 3-1. Final Assembly Parts and Kits (cont.)
Part or Kit Ordering Code Consists of Following Parts Figure/Item nr
Mounting Material Set 3981859
Self tapping Screw 10 mm (2x, to fix
input cover)
3-1 / 2
Dowel (6x, to fix straps) 3-1 / 4
Steel Plate for Lock 3-1 / 5
Self tapping Screw 16.5 mm (4x, to
fix Rear Case)
3-1 / 6
Screw M3x6 (2x, to fix bottom
holster)
3-1 / 8
Self tapping Screw (6x, 10.5 mm to
fix Main PCA Module to Front Case)
3-3 / 12
Side Strap 3945370 Can be fixed on Left or Right side ---
Hang Strap 946769
Can be fixed on Top Side of
Instrument
---
Bottom Holster Set 3981867
Bottom holster assy 3-1 / 7
Cover for USB 3-1 / 9
Cover for DC adapter power 3-1 / 10
Keypad 4 channels 3942805 --- 3-3/ 6
Keypad 2 ch. + meter 4035336 --- 3-3/ 6
Keypad Foil (all models) 3942810 (Incl. Flat Cable) 3-3 / 9
USB cable 3945381
USB-A to mini-USB-B (for PC
connection)
---
BNC Connector Red,
500 MHz
4306959 X1100
[1]
BNC Connector Blue,
500 MHz
4306967 X1300
[1]
BNC Connector Gray,
500 MHz
4306971 X1400
[1]
BNC Connector Green,
500 MHz
4306980 X1200
[1]]
BNC Connector Black,
500 MHz
4306998 ---
BNC Connector Red,
200 MHz
3945031 X1100
[2]
BNC Connector Green,
200 MHz
3945068 X1200
[2]
BNC Connector Blue,
200 MHz
3945046 X1300
[2]
---
BNC Connector Gray,
200 MHz
3945054 X1400
[2]
---
Banana Jack Black 4035403 X 1501 ---
Banana Jack Red 4035415 X 1500 ---
DC Power Input Socket 215785 X9100 ---
[1] Later PCA sub code 5
[2] Early PCA sub code 2 or firmware version 10.
Check that the serial number is 25375604. If yes, use the later connectors. If <25375604, evaluate the firmware and
subversion. To find the version, press in sequence, USER and F3 VERSION & CAL. If the firmware version is
<V11.00, use the early connectors. If the firmware is V11.10, check under subversions that the last datablock is x5xx
(for instance 2516). This value determines that the higher frequency adjust point should be used.
for x5xx: use the later connectors
for x2xx: use the early connectors