142
10-1-4. MFR-40RU
Buttons/Colors
40 buttons (3 colors: red/green/orange), user assignable
Number of
Connections
Max. 128 units (including Main, Remote and GPI units)
Interfaces
MFR-LAN
10/100BASE-TX RJ-45 x 1
(For connection to MU. A network hub required for multiple unit
configuration.)
SERVICE
RS-232C 9-pin D-sub (male) x 1 (for maintenance)
Temperature
0°C to 40°C
Humidity
30% to 85% (no condensation)
Power
+12 VDC Pin-connector x 2 (redundant power supply as standard)
Consumption
100 V AC to 120 V AC: 10 VA (5 W),
200 V AC to 240 V AC: 15 VA (7 W)
Dimensions
430(W) x 44(H) x 42(D) mm EIA 1 RU
Weight
2 kg
Consumables
AC adaptor: Replace every 5 years.
10-1-5. MFR-18RUA
Buttons/Colors
18 buttons (3 colors: red/green/orange), user assignable
OLED display x 18 (Max. 7 characters x 2 lines, Displayed above each
button) with Rotary selector
Number of
Connection
Max. 128 (including Main, Remote and GPI units)
Interfaces
MFR-LAN
10/100BASE-TX RJ-45 x 1
(For connection to MU. A network hub required for multiple unit
configuration.)
SERVICE
RS-232C 9-pin D-sub (male) x 1 (for maintenance)
Temperature
0°C to 40°C
Humidity
30% to 85% (no condensation)
Power
+12 V DC Pin-connector x 2 (redundant power supply as standard)
Consumption
100 V AC to 120 V AC: 14 VA (6 W),
200 V AC to 240 V AC: 18 VA (6 W)
Dimensions
430(W) x 44(H) x 42(D) mm EIA 1 RU
Weight
2 kg
Consumables