SEP user’s manual Page 67 of 89 Doc no. RD-7243-MA-001-02
9. Periodic maintenance
Maintenance may only be performed by qualified persons.
Please dispose of lubricants and spare parts in an environmentally responsible
manner.
Important! If work is needed under the platform, it is impossible to work under the
platform unless the platform is completely blocked from any spontaneous descending
movements. Use the "maintenance safety block (20030117) (1) installed on the rack. The
clearance under the platform must be a minimum of 6'-6" (2 m). Then lower the platform
so the clearance between the platform and safety block is less than 1" (25 mm). Use the
drop test remote control to move the platform during maintenance. REFER TO SECTION 10.1
DROP TEST PROCEDURE, ON PAGE 75 FOR THE REMOTE CONTROL INSTRUCTIONS.
Important! Never enter the space under the platform if the latter has not been
secured!
Important! Always turn of the power supply and padlock the disconnect switch to
the ground box (GC1) before installing the safety block and starting any work
under the platform!
Important! Immediately report any change or defect to the manufacturer or his authorised
representative. If necessary immediately stop and secure the platform.