SEP user’s manual Page 68 of 89 Doc no. RD-7243-MA-001-02
9.1. Daily maintenance
• Platform;
o Clear the platform of excess dirt, debris and snow/ice.
o Clean the proximity detector and the end travel detecor.
o Make sure the data plates and stickers are present, legible and in good condition on
the platform, protection mesh and anywhere required.
∞ REFER TO SECTION 4.10 DATA PLATES AND STICKERS, ON PAGE 31.
o At ground level, keep the space around the working zone of the platform clean and
cleared.
o Visually inspect the movement path of the platform and that it is clear of any
obstacles.
o Inspect the condition of the guide rollers.
• Protections;
o If present, inspect the ground protection mesh. Make sure the ground is firm and
solid. Check that the protection mesh adjustable footing is well adjusted to the
ground. Add shoring if necessary.
• Control;
o At ground level, check that the arms and rollers of the level limit switch are in good
condition and pivot easily.
o At every required level, make sure that the level detector pads are firmly attached
and in good working condition.
• Additional components;
Inspect the condition of the following items. Check for jamming, deformation and
breakage;
o Loading and unloading, tailgates of the platform.
o Installation tailgate platform.
o Landing doors.
o Platform floor.
o Railings.
o Plinth.
o Protection roof (if installed - optionnal).
• Electro-mechanical;
o Inspect the condition of the motorization.
o Inspect the condition of the main power supply.
o Inspect the condition of the power cables, cable guides and cable barrels. Look for
twists/derformations and sharp edges that may damage the cables.
• Operation;
Make a movement verification and make sure that:
o The end travel detectors are triggered at each floor and ground level.
o The tailgates interlock locks work adequately. It must not be possible to operate
(elevate or lower) the platform when one of the doors is opened
o All emergency stop buttons are in working condition. When pressed individually, it
must not be possible to operate (elevate or lower) the platform.
∞ REFER TO SECTION 7.12 EMERGENCY STOP BUTTON, ON PAGE 58.
o Platform movement immediately stops when a landing door is opened. Test all
landing doors.
o Make sure the machine stops immediately a few seconds when reaching 10'-0" (3m)
or less from the ground during descent. When the platform resumes its descent,
make sure the sound signal works during the rest of the descent, until reaching
ground level.
o Inspect the condition and function of the emergency descent system.
o While operating, someone must inspect the condition of the ground and of the load
distribution elements (legs with adjustable jacks, shoring, etc.).