9.5. Annual maintenance
Check the oil level in the engine gearboxes. Fill if necessary. Warning! Do not mix
mineral and synthetic oils when filling the tank.
SEE SUGGESTED GREASE PROVIDER IN SECTION 9.7 PERIODIC LUBRIFICATION, ON PAGE 72.
Check and test the condition of each mobile and/or adjustable component. Presence of
rust, wear and mechanical damage.
Check that the rack segments are solidly bolted to the mast section. Tightening torque
close to 240 ft/lb (325 Nm).
9.6. Three (3) years maintenance
The emergency centrifugal brake must be replaced once every three (3) years. Refer to
the data plate of the brake and contact your FRACO representative as needed.
Perform maintenance of the engine gearboxes once every three (3) years. Warning! Do
not mix mineral and synthetic oils when filling the tank.
SEE SUGGESTED GREASE PROVIDER IN SECTION 9.7 PERIODIC LUBRIFICATION, ON PAGE 72.