SEP user’s manual Page 76 of 89 Doc no. RD-7243-MA-001-02
IMPORTANT :
If the emergency brake is not triggered in the first 5'-0" (1,5 m) of the drop, release the
"TEST DE CHUTE/DROP TEST" (4) previous page and/or "ACTIVER/ENABLE" (5) previous
page button to stop the descent!
7. After the drop, elevate the platform by approximately 1'-0" (0,3 m) to release the emergency
brake by turning the selector of the remote control to the "HAUT/UP" (3) previous page
position.
8. Then lower the platform by turning the selector of the remote control to the "BAS/DOWN" (3)
previous page position. Maintain the selector in position until the automatic stop of the
platform at ground level.
9. Before reseting the brake, make sure the three (3) light indicators of the main control panel
(CC1) are turned off. If it is not the case, it means the brake activation detector is not well
adjusted.
∞ REFER TO 10.1.1 EMERGENCY BRAKE RESET, ON PAGE 77.
10. Reset the emergency brake system by following the reset procedure of the safety device
manual (SD2).
11. Fill the register (Fraco SD2 Data on safety device use) of the safety device manual.
12. Disconnect the drop test remote control (2) previous page turn the "WORK / STOP / DROP"
selector key (1) to the "MARCHE/ON" (1) previous page position.
For the reset procedure, refer to the instructions on the next page.